64619 90 W 14.5 V

Product family features
  • Xenon instead of krypton as the filler gas (XENOPHOT HLX versions)
  • Luminous flux up to 10 % higher with same power consumption (XENOPHOT HLX versions)
Areas of application
  • Microscopy
  • Laboratory & Analysis
  • UV Curing
  • Fiber Illumination
  • Surgical & Dental Overhead
Safety advice
To prevent personal injury or damage to property, halogen lamps may only be operated in suitable luminaires designed with suitable mechanisms (protective shields, grids, etc.) to ensure that in the event of a lamp bursting no parts/shards can escape and that during operation no ultraviolet radiation can escape. There must also be a warning sign to indicate that the lamps give off high levels of heat. Detailed information is available on request.
NON HOUSEHOLD ILLUMINATION Medical pictogram

Technical Data

General Product Information

Global order reference

64619

ANSI code

EPX

Electrical Data

Nominal wattage

90 W

Nominal voltage

14.5 V

Type of current

AC

Photometric Data

Nominal luminous flux

43 lm

Color rendering index Ra

100

Focal length

155.0 mm

Physical Attributes & Dimensions

Lamp base

GX5.3

Diameter (in)

2.008 in

Diameter

51.0 mm

Length

45.0 mm

Coating

True

Product weight

30.00 g

Operating Conditions

Burning position

Other

Cooling

Forced

Minimum diameter of lamp enclosure

51.0 mm

Lifetime Data

Nominal lifetime

500 hr

Environmental & Regulatory Information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Primary article identifier

4050300017273

Declaration no. in SCIP database

In work

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4050300017273 FS

FOLDING BOX

1 44mm x 44mm x 54mm 36.00g 0.11dm³
4050300225289 VS

SHIPPING BOX

50 295mm x 115mm x 246mm 1591.00g 8.35dm³

Country specific information

EAN

METEL code

4050300017273 OSRH64619